Kramer.Firm's Cable Television System Photos

From Cable TV Systems in the USA


Home :: Upload file :: Login
Album list :: Last uploads :: Last comments :: Most viewed :: Top rated :: My Favorites :: Search

Home > Cable TV Systems > Cable TV - Outside Plant

Last additions - Cable TV - Outside Plant
Splitter Tap.jpg
Multi-Purpose Splitter Tap1305 viewsWe probably all have seen this before. A tap used as a splitter with a pin to f connector on the seizure screw Feeding a customer with R.F. along with A.C.Oct 04, 2006
leakage.repair.kit.jpg
Leakage Repair Kit - Removed From System2139 viewsThis leakage repair kit was recently removed from a system after a rebuild. It's just the right size for .750 cable. We're unclear whether the can-brand had any special leakage control properties, but we can guess it had special properties for the person who had to drain the can for this most important use.

This is not a staged photo: This REALLY came out of a system.
Apr 20, 2006
alum.foil.black.tape.leakage.control.big.jpg
Leakage Control - The Good Old Way1986 viewsClose up of how to stop a leaky system. Just use foil and black tape!Apr 20, 2006
alum.foil.black.tape.leakage.control.jpg
Leakage Control - The Good Old Way1472 viewsDo Tree Rats Love Cable? I think the answer is YES.Apr 20, 2006
DSC00040.JPG
Improper Pole Attachment2533 viewsOne of those situations where you use whatever is handy when you dont have the right part. Check the next photo for an indication of the destructive nature of this pole attachment. Apr 04, 2005
DSC00042.JPG
Damage to telephone pole.2412 viewsNote the wear damage to this pole as a result of the rubbing action of a logging chain used as a temporary although apparently permanent pole attachment. It is only a matter of time.....Apr 04, 2005
DSC00039.JPG
A little bit close to power.2262 viewsCable strand and cable passes THROUGH the power loops of the transformer. Strand clamp is mounted too close to power. Note second cable operator mounted on stand off bracket to provide required clearance. Apr 04, 2005
DSCN1176.JPG
Plant Interfering with Power Co. Switch Bar2167 viewsThe cable TV plant isn't properly attached to the pole. The plant is held by a rope attached to the RAMS HEAD down guy attachment. The cables are pushing against the power company breaker push rod.Jan 11, 2005
DSCN1181.JPG
Loose Distribution Cable1875 viewsUse of coaxial tails to hold plant to strand. Also notice the loose cables to the power supply attached at the far pole (right side of photograph).Jan 11, 2005
DSCN1185.JPG
Loose Distribution Cable over Trolley Lines1661 viewsUse of coaxial tails to hold plant to strand over energized trolley wires.Jan 11, 2005
DSCN1188.JPG
Loose Plant hanging from mule tape.2005 viewsOld plant is tied up to the telephone pole by means of mule tape. Jan 11, 2005
DSCN1150.JPG
Yellow rope: It makes it much easier to find bad things.1861 viewsThe yellow rope is holding up new plant at a mid-intersection cross-over solely by securing the plant via the rope to the strand clamp. This is over a busy intersection. Should the rope fail, it will drop the cables into the intersection. Jan 11, 2005
DSCN1155.JPG
Open power supply1865 viewsWe found this power supply open and exposed to the elements. Note that the power supply module is sitting on top of several sheets of flammable foam rubber in an attempt to quiet the transformer hum. Jan 11, 2005
DSCN1165.JPG
Extension cord power supply1726 viewsThis picture shows two power supplies mounted on the same pole. Note that the lower power supply is being furnished power via a piece of extension cord cable running from the top power supply. Not an NEC acceptable method of powering. Jan 11, 2005
DSCN1166.JPG
Extension Cord Power Supply, Close-up view1594 viewsThis picture shows how the normal flextite power entrance conduit has been removed from the bottom of the power supply in order to permit the installation of a piece of regular extension cord cable to be installed to service the power supply mounted below. Very unsafe and not code compliant.Jan 11, 2005
cable.to.ca.erbes.PB120014.jpg
Why cables should not rest on traffic signal arms #1 of 21796 viewsWhen plant is allowed to rest on traffic signal arms (or light standard arms, etc.) eventually wear will occur as the cables rub the arm. This will result in plant problems, and can damage the traffic signal arm, too.Nov 13, 2004
cable.to.ca.erbes.PB120015.jpg
Why cables should not rest on traffic signal arms #2 of 21770 viewsIn this close-up of a cable TV distribution cable, you can clearly see the effects of wear on the cable. Eventually this line will wear through, fail, radiate signals, and permit ingress to impact picture quality.Nov 13, 2004
DSC02970small.jpg
When the Rubber Meets the Power Supply #22539 viewsIn this close-up you can see how the tech was creative in his/her use of the rain pants and duct tape! Mar 14, 2004
smallDSC02966.jpg
When the Rubber Meets the Power Supply1972 viewsHow creative! Using the rubberized pants from a rain suit (plus some duct tape) to cover a power supply module sitting atop a power supply cabinet!Mar 14, 2004
DSC02920.JPG
Oops! Something fell out!2413 viewsSaddly, this power supply seems to have suffered a hernia. The power coupler seems to have fallen out of the, ah, guts of the power supply. Mar 14, 2004
S2010001.JPG
No security2088 viewsOld cable tv plant with no apparent signs of maintenance.Mar 02, 2004
catv-AlumFoil.jpg
How to Control Signal Leakage2984 views...just used aluminum foil to cover offending connectors.Feb 08, 2004
vaultimage004.jpg
Waiting To Bite2301 viewsI don't want to be the poor hapless sole who steps on this cable TV vault and lid, especially at night. That is, of course, unless I know of a good tort attorney.Feb 08, 2004
alphasimage003.jpg
Security Bars Not A Bar to Entry2574 viewsHere are two Alpha power supplies equiped with add-on security bars (think: Soft Drink vending machines at gas stations). The vandals going after the batteries found these security bars to be, well, no bar to entry! Feb 08, 2004
DSC01454.JPG
Where did THIS pole come from???2516 viewsUnsecured power supply. Jan 21, 2004
DSC01435.JPG
Double your power, double your loss....2015 viewsOpen power supply. Not secured as required by NEC. Invitation to vandalism or theft. Potential safety hazard to public. Jan 21, 2004
DSC01433A.jpg
This looks more like modern art than splicing!!2359 viewsVery poor rebuild splicing. Interference to telephone facilities. reliability problems. Jan 21, 2004
DSC01423A.jpg
You are way out of line on this...2108 viewsStrand pulled seriously out of line. This cable is substantially pulled out of the pole line due to tension from a span over an intersection. Jan 21, 2004
DSC01037A.jpg
Clean this up1745 viewsBroken lashing wire. Drops not properly secured to pole. Drop maintenance. Jan 21, 2004
DSC01012A.jpg
Multiple infractions here1605 viewsPoor workmanship, anchoring, loose down guys, loose bonds. Potpourri here. Jan 21, 2004
DSC00984A.jpg
Just laying around1753 viewsAccording to a local report, this coil of fiber has been sitting at the bottom of this pole for over a year. Incomplete rebuild construction. Jan 21, 2004
DSC00982A.jpg
Here we go loop de loop!1473 viewsIncomplete fiber construction. Fiber slack loops and splice case left dangling, secured by ty-wraps. Interferes with telephone facilites. Jan 21, 2004
DSC00975A.jpg
Not quite finished here.1602 viewsIncomplete and sloppy rebuild construction. Riser conduits not properly trimmed to length. Cables not secured. Cable straps not tightened. Jan 21, 2004
DSC00968A.jpg
It's not a pole step!!1718 viewsThis junction box for the electrical wiring for this power supply box was not intended as an apparent pole step. This damaged wire receptical has wiring exposed to the elements now and open to water intrusion. Jan 21, 2004
DSC02070.JPG
We have enough now, you can stop pushing.!!!1920 viewsUnsecured cables and conduit pole risers. Excess conduit is hanging loose and not properly secured. Jan 21, 2004
DSC02061.JPG
OOPs, forgot to tighten the nut.1541 viewsCable bracket has become detached from a horizontal support arm. Jan 21, 2004
DSC02050.JPG
Rope is always a handy thing to have ...1549 viewsCable slack span supported by rope. This is the result of a pole changeout in which the new pole was place further streetside of the existing pole, creating a gap between the existing deadend and the new pole. Solved by installing a rope attached to the strand. Incomplete pole changeout. Jan 21, 2004
DSC02042.JPG
Blowing in the wind...1230 viewsAbandoned rebuild riser cables. Exposed and loose cable stubs abandoned and left over from design changes as part of a rebuild. Removed from service, but not physically removed or properly secured to prevent damage or injury. Jan 21, 2004
DSC02023.JPG
Ahoy mates. You forgot to drop anchor!!!1251 viewsMissing anchor guys. This end of the line is not supported by the required dead end guys. Jan 21, 2004
DSC02011.JPG
Lets find some time to bond....1198 viewsLoose strand and bonds. Cable plant is not correctly bonded together with appropriate clamps. Jan 21, 2004
DSC02007.JPG
This could be a shocking experience...1571 viewsPower cables endanger cable plant. In this photo, the secondary power cable conductors extend down to the level of the cable strand. The conductors interfere with access to the cable space and are a hazard to workers. Jan 21, 2004
DSC01269.JPG
Let it all hang out1508 viewsPoor drop maintenance. Drops interfere with telephone facilites. Jan 21, 2004
DSC01281.JPG
I don't think we are quite finished here.1101 viewsIncomplete rebuild construction. Fiber bundle coiled and secured to strand. Interferes with telephone facilites and cables. Jan 21, 2004
DSC01302.JPG
Hang em high1111 viewsLow cable plant over an intersection held up by tying it to power. Jan 21, 2004
DSC01308.JPG
Can you toss a football through this??1141 viewsImproper fiber storage. Loop interferes with and rubs against telephone cables. Jan 21, 2004
DSC01319.JPG
Just let it all hang down1070 viewsOld cable plant cut and dropped into the tree limbs as part of a rebuild. Contractor failed to wreckout the old plant creating a safety hazard. Jan 21, 2004
DSC01335.JPG
OK, What happened to the pole vaulter?1263 viewsFiber riser not secured to the pole, nor was it properly trimmed to length. Jan 21, 2004
DSC01369.JPG
Rope, I Need more rope!!!1409 viewsRiser cables not properly secured or covered on pole. Note the use of 'mule' tape. Jan 21, 2004
DSC01376.JPG
Incomplete pole transfer. (Incomplete pole!)1687 viewsWhen a pole transfer is not promptly completed damage to the plant can occur. Here, the remaining portion of this pole stub has damaged and bent the coaxial cable due to the weight. This can result in poor picture quality for some/many subscribers. Jan 21, 2004
DSC01377.JPG
I said, "You can stop pulling now"996 viewsExtra unsecured conduit risers. Excess length. Left hanging as excess conduit as rebuild passed. Jan 21, 2004
DSC01372.JPG
Thats a wrap. Lets finish this some other time!1184 viewsRiser cover not properly secured to the pole. Note the use of the tape to hold the riser to the pole. Jan 21, 2004
DSC01356.JPG
Now that is what I call "Air Cooled"1419 viewsOpen and unsecured power supply. Jan 21, 2004
DSC01358.JPG
How do you get up this pole??1241 viewsClimbing space violation. Distribution cable completely wraps the pole.Jan 21, 2004
DSC01363.JPG
You can stop pulling now!!!1779 viewsFiber riser conduits not trimmed, nor covered, not properly secured. Excessively long. Poor workmanship. Jan 21, 2004
grdDSC00805.jpg
I know there is a phone terminal in here somewhere!!!!1740 viewsLoose cable drops interfere with maintenance of telephone facilities. This is where drop slack storage and maintenace is important. Jan 20, 2004
grdDSC00737.jpg
Is this a rats nest, or what??1846 viewsDue to insufficient clearances between cable and telephone, this rats nest of drop wiring interferes with both parties and is a hazard to maintenance personnel. Jan 20, 2004
grdDSC00729.jpg
You're rubbing me the wrong way...2115 views Strand mounted cable equipment is interfering with access to the telephone splice case. Jan 20, 2004
DSC00094.JPG
Power supply in a box1659 viewsDuring a recent rebuild, this operator decided it was more convenient to place a temporary power supply on top of the old one. They even went so far as to leave it in its original "protective" packaging, and connect it via an extension cord pinched in the door of the cabinet. Multiple NEC code violations.Jan 20, 2004
DSC00807.JPG
Incomplete fiber construction. Excess fiber loops.1159 viewsIn this photo, a substantial amount of fiber slack is coiled up and hanging from strand, secured by a rope. As a temporary measure during construction, this sometimes occurs for short periods of time, but as a permanent solution to slack storage, it is inappropriate and inconsistent with code. Jan 20, 2004
DSC01833.jpg
Why bury, we have bushes to hide it.2237 viewsIn this picture, a replacement drop has been installed utilizing the new drop-in-duct product and rather than bury the DIC, the installation crew merely ran it through the bushes to the pedestal, laying it on the surface of the ground. Jan 19, 2004